EDMLELDV - IS-U: User exit - independent validations
CPI1466 during Backup SUBST_MERGE_LIST - merge external lists to one complete list with #if... logic for R3upThis documentation is copyright by SAP AG.
Enhancement
You can use the function modules for this enhancement to program your own independent validation.
Note
Proceed as follows:
- Define the validation class.
- (Customizing: Device Management -> Meter Reading -> Validations -> Independent Validations). Define Validation Classes.
- You program a maximum of twelve exit function modules in enhancement EDMLELDV.
- (Transaction CMOD)
- Structure X_REABLD is transferred to the function module. The structure contains information about the meter reading document to be validated. All relevant meter reading reasons are transferred.
- If exception PLAUSI_ERROR is triggered, the meter reading result is defered.
- Define separate independent validations.
- (Customizing: Tools -> System Modifications -> User-Defined Validations -> User-Defined Independent Validations -> Define Customer-Specific Independent Validations) Define Customer-Specific Independent Validations.
- Allocate one of the exit function modules and if necessary a screen, to your own independent validation.
- (Customizing: Tools -> System Modifications -> User- Defined Validations -> User-Specific Independent Validations -> Allocate Customer-Specific Validations to Function Modules). Allocate Customer-Specific Validations to Function Modules.
- Allocate the independent validations to a validation class.
- (Customizing: Tools -> System Modifications -> User-Defined Validations -> User-Defined Independent Validations -> Allocate Customer-Specific Validations to Validation Classes) Allocate Customer-Specific Validations to Validations Classes.
Recommendation
Choose a number from interval 50 - 99 for your validation.
Example
Check whether a meter overflow is expected in the next period.
- Select a free function modules such as EXIT_SAPLEPU1_001. Code your validation.
- If necessary create a subscreen with validation-specific data. This subscreen is called up by pressing the correction button.
- Maintain entries under: Allocate Customer-Specific Validations to Function Modules as follows:
- Field IV: 50
- Field Fmod: 001
- Field Screen: 100