Ansicht
Dokumentation
CPA5793 - Network interface &30 failed. No response from NT. (C G R) ( OS/400 )
General Material Data BAL_S_LOG - Application Log: Log header dataThis documentation is copyright by IBM.
Message : CPA5793
Network interface &30 failed. No response from NT. (C G R)
Message Long Text :
Cause . . . . . : The ISDN physical interface (NT) could not be activated. One possible problem is that the values specified for the activation timers for network interface &30 are too small.
Recovery . . . : Verify that the NT is operational and the system is properly connected to the NT. Then do one or more of the following:
-- Use the WRKNWID command to change the activation timers (ACTTMR and REACTTMR parameters).
-- Reply to the message.
If the problem continues, press F14 to run problem analysis.
Possible choices for replying to message . . . . . . . . . . . . . . . :
C -- Cancel recovery and inform any applications and subsystems that are waiting for an operation that the recovery has been canceled.
G -- Start the automatic communications recovery again as defined by the communications recovery limit (CMNRCYLMT) configured for network interface &30.
R -- Try again one more time.
Technical description . . . . . . . . : The error log identifier is &22.
The error code is &40: ISDN physical interface did not activate.
Message File : QCPFMSG
Library Message File : QSYS2924
General Material Data ABAP Short Reference
This documentation is copyright by IBM.
Length: 3259 Date: 20240329 Time: 142946 sap01-206 ( 3 ms )