CPA57C6 - Controller &24 failed. No data received. (C G R) ( OS/400 )
CPI1466 during Backup ROGBILLS - Synchronize billing plansThis documentation is copyright by IBM.
Message : CPA57C6
Controller &24 failed. No data received. (C G R)
Message Long Text :
Cause . . . . . : The probable causes are:
-- Remote system problem.
-- Network problem.
-- Local configuration problem.
Recovery . . . : Do one or more of the following:
-- Ask the remote system operator to verify the remote system configuration.
-- Ask the network operator to verify that the network is operating correctly.
-- Use the Change SDLC Line Description (CHGLINSDLC) command to increase the inactivity timer (INACTTMR parameter) value in line description &23.
If the problem continues, press F14 to run problem analysis.
Possible choices for replying to message . . . . . . . . . . . . . . . :
C -- Cancel recovery and inform any applications that are waiting for an operation that the recovery has been canceled.
G -- Start the automatic communications recovery again as defined by the communications recovery limit (CMNRCYLMT) parameter specified in the controller description.
R -- Try the operation one more time.
Technical description . . . . . . . . : The error log identifier is &22. The error code is &40. Reason codes and their meanings follow:
4400266A -- The inactivity timer lapsed for a short hold mode station.
Message File : QCPFMSG
Library Message File : QSYS2924