Ansicht
Dokumentation

CPA5874 - Controller &24 failed. Facility field too long. (C G R) ( OS/400 )

CPA5874 - Controller &24 failed. Facility field too long. (C G R) ( OS/400 )

General Data in Customer Master   SUBST_MERGE_LIST - merge external lists to one complete list with #if... logic for R3up  
This documentation is copyright by IBM.
SAP E-Book


Message : CPA5874
Controller &24 failed. Facility field too long. (C G R)

Message Long Text :

Cause . . . . . : The local system did not send an X.25 call out request for controller &24 on line &23 because the facility field length exceeds the maximum allowed (109 bytes).
Recovery . . . : The total length of the facilities encoded by the local system on a given X.25 call out request is determined by the following configuration parameters:
-- Length of value specified in the user facility (USRFCL) parameter for controller &24.
-- Length of value specified plus two in the network user identifier (NETUSRID) parameter for line &23.
-- If the value specified in the default packet size (DFTPKTSIZE) parameter for controller &24 is not *LIND, and is different from that specified in the default packet size (DFTPKTSIZE) parameter for line &23, then three bytes are added for this facility.
-- If the value specified in the default window size (DFTWDWSIZE) parameter for controller &24 is not *LIND, and is different from that specified in the default window size (DFTWDWSIZE) parameter for line &23, then three bytes are added for this facility.
-- If a value is specified in the user group identifier (USRGRPID) parameter for controller &24, then two bytes are added for this facility.
-- If a value other than *NONE is specified in the X.25 reverse charging (RVSCRG) parameter for controller &24, then two bytes are added for this facility.
Change one or more of the above parameters to reduce the total length of the facility field to less than or equal to 109 bytes.
If the problem continues, press F14 to run problem analysis.
Possible choices for replying to message . . . . . . . . . . . . . . . :
C -- Cancel recovery and inform any applications and subsystems that are waiting for an operation that the recovery has been canceled.
G -- Start the automatic communications recovery again as defined by the communications recovery limit (CMNRCYLMT) configured for controller &24.
R -- Try the operation one more time.
Technical description . . . . . . . . : The error log identifier is &22.
The error code is &40: Facility field exceeded the maximum length allowed by CCITT Recommendation X.25 and ISO 8208 (109 bytes).

Message File : QCPFMSG
Library Message File : QSYS2924


CPI1466 during Backup   General Material Data  
This documentation is copyright by IBM.

Length: 3265 Date: 20240425 Time: 025644     sap01-206 ( 2 ms )