CPA59C1 - Controller &24 failed. Probable internal system failure. (C G R) ( OS/400 )

CPA59C1 - Controller &24 failed. Probable internal system failure. (C G R) ( OS/400 )

Fill RESBD Structure from EBP Component Structure   ROGBILLS - Synchronize billing plans  
This documentation is copyright by IBM.
SAP E-Book


Message : CPA59C1
Controller &24 failed. Probable internal system failure. (C G R)

Message Long Text :

Cause . . . . . : The remote controller is receiving synchronous data link control (SDLC) data that is not valid. The input/output processor (IOP) may be failing and sending SDLC data that is not valid, or the buffers in the remote controller may have overflowed.
Recovery . . . : Have the remote system operator verify that the remote system is operational.
Then do one of the following:
-- Type C to cancel recovery and to inform any applications that are waiting for an operation that the recovery has been canceled.
-- Type G to start the automatic communications recovery again as defined by the system communications recovery limit (CMNRCYLMT) for line &23.
-- Type R to try the operation one more time.
If the problem continues, press F14 to run problem analysis.
Possible choices for replying to message . . . . . . . . . . . . . . . :
C -- Cancel.
G -- Start automatic recovery again.
R -- Try again one more time.
Technical description . . . . . . . . : The error log identifier is &22.
The error code is &40: An SDLC frame reject was received from the remote controller. The buffers in the controller may have overflowed.

Message File : QCPFMSG
Library Message File : QSYS2924


Addresses (Business Address Services)   BAL_S_LOG - Application Log: Log header data  