Ansicht
Dokumentation
CPD5105 - Attributes of field not valid. ( OS/400 )
SUBST_MERGE_LIST - merge external lists to one complete list with #if... logic for R3up CPI1466 during BackupThis documentation is copyright by IBM.
Message : CPD5105
Attributes of field not valid.
Message Long Text :
Cause . . . . . : The field specified for the cursor-position parameter on the RTNCSRLOC keyword must be defined as signed numeric (S in position 35) of length 4 with 0 decimal places and hidden (H in position 38).
Recovery . . . : Either change the attributes of the indicated field, or change the field name specified for the mode parameter of the RTNCSRLOC keyword. Then try the request again.
Message File : QCPFMSG
Library Message File : QSYS2924
Vendor Master (General Section) General Material Data
This documentation is copyright by IBM.
Length: 3212 Date: 20240418 Time: 184426 sap01-206 ( 3 ms )