Ansicht
Dokumentation

CPD5CCC - Data import not compatible with data export for symbol &1. ( OS/400 )

CPD5CCC - Data import not compatible with data export for symbol &1. ( OS/400 )

General Data in Customer Master   BAL_S_LOG - Application Log: Log header data  
This documentation is copyright by IBM.
SAP E-Book


Message : CPD5CCC
Data import not compatible with data export for symbol &1.

Message Long Text :

Cause . . . . . : Data item '&8' was imported by module &2 in library &3, and exported by *&4 &5 in library &6. The data import is not compatible with the data export. The reason code is &7. The reason codes are:
-- 010D - The thread local static (TLS) storage attribute of the import is not compatible with the TLS storage attribute of the export.
-- 010E - The import is TLS storage, but the import is unresolved. This usage is not supported.
-- 010F - The import is TLS storage, but the matching export is dynamic data. This usage is not supported.
Recovery . . . : Make the required changes, then try the command again.

Message File : QCPFMSG
Library Message File : QSYS2924


General Material Data   ROGBILLS - Synchronize billing plans  
This documentation is copyright by IBM.

Length: 3246 Date: 20240420 Time: 152813     sap01-206 ( 3 ms )