QWM1939 - Global variable prompting is not allowed in batch mode. ( OS/400 )

QWM1939 - Global variable prompting is not allowed in batch mode. ( OS/400 )

CPI1466 during Backup   CPI1466 during Backup  
This documentation is copyright by IBM.
SAP E-Book


Message : QWM1939
Global variable prompting is not allowed in batch mode.

Message Long Text :

Cause . . . . . : You tried to use the variable "&1" before it was set. Prompting for variables cannot be done in batch mode.
Recovery . . . : If you are using the STRQMQRY command you can set variable "&1" by using the SETVAR keyword. If variable "&1" is being used in a Query Management procedure, put a SET GLOBAL query command in the procedure to give the variable a value. If variable "&1" is being used through the Query Management callable programming interface your program should be changed to use the SET GLOBAL query command. After you set the variable, try the request again.

Message File : QCPFMSG
Library Message File : QSYS2924