:T IDLC short frame errors exceeded guideline of &2.

Nachrichtenlangtext :

Cause . . . . . : The number of short frames received has exceeded the threshold value given by the system. One of the following may have caused the problem:
-- The environment may be electrically noisy.
-- The ISDN line quality may be poor.
-- Contact problems with the ISDN cable connectors.
Recovery . . . : You may choose to ignore this message because your line is operational. Refer to planning guides for information about electrical requirements and noise problem considerations. Consult your local ISDN network provider to have the line tested to verify line quality. Check that the cable is securely connected to the appropriate receptacles and the cable is in good physical condition. You may change the frequency of occurrence of this message by adjusting the value of the SHORTFRAME and THRESHOLD parameters, using the CHGLINIDLC command.
Technical description . . . . . . . . : The following table shows the line and network interface (NWI) identifiers, maximum short frame error (SFE) rate (errors per 15 minutes), the number of intervals that had an SFE rate above the guideline, and the date and time the maximum rate occurred.
:I PFX2099
:T PFX209806

A sufficient number of short frame errors were detected over time such that the error counter exceeded the threshold limit. A short frame is a frame with less than five bytes.