Ansicht
Dokumentation
PLI1200 - UNDERFLOW condition raised at &4 in &3. ONCODE &1. ( OS/400 )
ROGBILLS - Synchronize billing plans BAL Application Log DocumentationDiese Dokumentation steht unter dem Copyright der IBM.
Nachricht : PLI1200
UNDERFLOW condition raised at &4 in &3. ONCODE &1.
Nachrichtenlangtext :
Cause . . . . . : The value of the exponent from the floating point operation is too small for the format of the specified receiver. The exponent value must be greater than -127 for short format floating point, and greater than -1023 for long format floating point. Processing continues but the result will be unpredictable.
Recovery . . . : Change the value of the exponent or change the format of the receiver.
Nachrichtendatei : QPLIMSGE
Bibliothek Nachrichtendatei : QSYS
ROGBILLS - Synchronize billing plans General Data in Customer Master
Diese Dokumentation steht unter dem Copyright der IBM.