PLI1906 - ERROR condition at &4 in &3. ONCODE &1. ( OS/400 )
BAL Application Log Documentation CPI1466 during BackupDiese Dokumentation steht unter dem Copyright der IBM.
Nachricht : PLI1906
ERROR condition at &4 in &3. ONCODE &1.
Nachrichtenlangtext :
Cause . . . . . : The reference to a pointer or numeric data item does not have correct alignment. This error can occur when you use a based or parameter item and either the basing pointer or the corresponding parameter argument does not have the correct boundary alignment.
Recovery . . . : Remove the UNALIGNED attribute if it was used on the argument or base numeric item. Check the basing pointer to make sure it was set to the correct address.
Nachrichtendatei : QPLIMSGE
Bibliothek Nachrichtendatei : QSYS