Ansicht
Dokumentation

icm/max_timeout_wp - Maximum Timeout in ms until ICM Worker Thread rolls out

icm/max_timeout_wp - Maximum Timeout in ms until ICM Worker Thread rolls out

Fill RESBD Structure from EBP Component Structure   ABAP Short Reference  
This documentation is copyright by SAP AG.
SAP E-Book
------------------------------------------------------------------------
| Parameter : icm/max_timeout_wp |
------------------------------------------------------------------------
------------------------------------------------------------------------
| Short Description : Max. Timeout before ICM worker thread rolls out |
------------------------------------------------------------------------
------------------------------------------------------------------------
| Parameter description : |
| ----------------------- |
| This parameter specifies how long an ICM worker thread should wait |
| for data from the network or from the server before the connection |
| is transferred to a dedicated monitoring (watchdog) thread for |
| monitoring. |
| The parameter does not normally need to be changed. An increase in |
| the parameter value leads to an increased requirement for ICM |
| worker threads. |
| |
| |
------------------------------------------------------------------------
------------------------------------------------------------------------
| Application Area : ICM |
------------------------------------------------------------------------
------------------------------------------------------------------------
| Unit: Milliseconds |
------------------------------------------------------------------------
------------------------------------------------------------------------
| Default value : 500 |
------------------------------------------------------------------------
------------------------------------------------------------------------
| Who is permitted to make changes: The customer |
------------------------------------------------------------------------
------------------------------------------------------------------------
| Limitations for operating systems: |
------------------------------------------------------------------------
------------------------------------------------------------------------
| Limitations for database systems: |
------------------------------------------------------------------------
------------------------------------------------------------------------
| Other Parameters Affected or Dependent: |
------------------------------------------------------------------------
------------------------------------------------------------------------
| Valid entries, formats, areas : Integer |
------------------------------------------------------------------------

------------------------------------------------------------------------
| Short Description : Maximum Timeout in ms until ICM Worker Thread rolls out
------------------------------------------------------------------------

------------------------------------------------------------------------
| Applications Area : ICM
------------------------------------------------------------------------

------------------------------------------------------------------------
| Parameter Type : I
------------------------------------------------------------------------

------------------------------------------------------------------------
| Changes allowed : X
------------------------------------------------------------------------

------------------------------------------------------------------------
| Valid for Operating System : *
------------------------------------------------------------------------

------------------------------------------------------------------------
| Dynamic switchable :
------------------------------------------------------------------------

------------------------------------------------------------------------
| Same on all Servers :
------------------------------------------------------------------------

------------------------------------------------------------------------
| Minimum : 0
------------------------------------------------------------------------

------------------------------------------------------------------------
| Maximum : 3600000
------------------------------------------------------------------------


Fill RESBD Structure from EBP Component Structure   ROGBILLS - Synchronize billing plans  
This documentation is copyright by SAP AG.

Length: 5170 Date: 20240420 Time: 180726     sap01-206 ( 5 ms )