Ansicht
Dokumentation

snc/data_protection/min - Min. required data protection for incoming connections

snc/data_protection/min - Min. required data protection for incoming connections

Addresses (Business Address Services)   Vendor Master (General Section)  
This documentation is copyright by SAP AG.
SAP E-Book
------------------------------------------------------------------------
| Parameter : snc/data_protection/min |
------------------------------------------------------------------------
------------------------------------------------------------------------
| Short description : Minimum required data protection for |
| Secure Network Communications |
------------------------------------------------------------------------
------------------------------------------------------------------------
| Parameter description : |
| ----------------------- |
| This parameter specifies the lowest requirement for data transfer |
| protection for incoming connections. |
The SNC layer attempts to reach at least this level of protection
| with the partner for incoming connections. Otherwise an error |
| is reported, and the affected connection |
| is cancelled. |
------------------------------------------------------------------------

------------------------------------------------------------------------
| Work area : SNC |
------------------------------------------------------------------------

------------------------------------------------------------------------
| Unit : Integer value |
------------------------------------------------------------------------

------------------------------------------------------------------------
| Default value : 2 (Data integrity protection) |
------------------------------------------------------------------------

------------------------------------------------------------------------
| Who is permitted to make changes: The customer |
------------------------------------------------------------------------

------------------------------------------------------------------------
| Limitations for operating systems : None |
------------------------------------------------------------------------

------------------------------------------------------------------------
| Limitations for database systems : None |
------------------------------------------------------------------------

------------------------------------------------------------------------
| Other Parameters Affected or Dependent: |
| %%snc/enable%% - Activate the SNC module |
| (Secure Network Communications) |
| %%snc/data_protection/use%% - default level for data transfer |
| protection |
| %%snc/data_protection/max%% - Restriction of data transfer |
| protection upwards |
------------------------------------------------------------------------

------------------------------------------------------------------------
| Valid Input, Formats, Areas: |
| <= %%snc/data_protection/use%% |
| 1 (Secure authentication only) |
| 2 (Data integrity protection) |
| 3 (Data privacy protection) |
------------------------------------------------------------------------


------------------------------------------------------------------------
| Short Description : Min. required data protection for incoming connections
------------------------------------------------------------------------

------------------------------------------------------------------------
| Applications Area : SNC
------------------------------------------------------------------------

------------------------------------------------------------------------
| Parameter Type : I
------------------------------------------------------------------------

------------------------------------------------------------------------
| Changes allowed : X
------------------------------------------------------------------------

------------------------------------------------------------------------
| Valid for Operating System : *
------------------------------------------------------------------------

------------------------------------------------------------------------
| Dynamic switchable :
------------------------------------------------------------------------

------------------------------------------------------------------------
| Same on all Servers :
------------------------------------------------------------------------

------------------------------------------------------------------------
| Minimum : 1
------------------------------------------------------------------------

------------------------------------------------------------------------
| Maximum : 3
------------------------------------------------------------------------