Ansicht
Dokumentation

09303 - SXC 1.54

09303 - SXC 1.54

rdisp/max_wprun_time - Maximum work process run time   Fill RESBD Structure from EBP Component Structure  
This documentation is copyright by SAP AG.
SAP E-Book

SXC 1.54

Additional information concerning the problem Chris & myself are
experiencing.

We have just installed the SXC 1.54 on an NT 4.0 Server. We have
managed to get all services starting successfully on the exchange
server, however we are having problems with the RFC connection in
our R/3 4.6C. We have entered the following information in SM59:-

Name SXC_OUT
Description SXC Test e-mail
Connection type T
Activation type Registration
Program ID SXC
Gateway host eitstsap.nmhgmcz1
Gateway service sapgw00

The eitstsap.nmhgmcz1 is the host name for the exchange server. The
ac4sap02 and sapgw01 is the hostname for the AS400 hostname and
gateway

It is failing with the following information.

ERROR Partner not reached(host eitstsap.nmhgmcz1,service sapgw00)
LOCATION Gateway on host ac4sap02.nmhg.com / sapgw01
DETAIL NiPConnect2
CALL SO_ERROR
COMPONENT NI (network interface)
COUNTER 15795
ERROR TEXT A remote host refused an attempted connect operation.
ERROR NUMBER 3425
MODULE nio4i.c
LINE 1059
RETURN CODE -10
SUBRC 0
RELEASE 46D
TIME Tue Feb 11 02:54:46 2003#
VERSION 34

Initially we thought the problem was on the set up of the RFC
connection, but now we believe the problem lies on the Exchange
server. We have an entry for sapgw00 in the services file on the
exchange server but still get the same error as above even when we
perform a niping -c -H eitstsap.nmhgmcz1 -S sapgw00 from a PC.

*********************************************************************
*
* ERROR partner not reached (host eitstsap.nmhgmcz1, service
sapgw00)
*
* TIME Mon Feb 10 13:57:15 2003
* RELEASE 46D
* COMPONENT NI (network interface)
* VERSION 34
* RC -10
* MODULE ninti.c
* LINE 1008
* DETAIL NiPConnect2
* SYSTEM CALL SO_ERROR
* ERRNO 10061
* ERRNO TEXT WSAECONNREFUSED: Connection refused
* COUNTER 1
*
*********************************************************************

Any help would be much appreciated,

With regards,
Steven Glennie
Basis Administrator
NACCO Materials Handling Group




- In DoNotReply@consolut.eu, "Anderson, Doreen"
<dandersoZb...> wrote:
> Chris - in your message below, there are 2 different SAPGW00 & 01
> referenced
> You may want to double check which GW instance you are truly going
out
> and make sure can ping from there
>
> Doreen
>
>
> -----Original Message-----
> From: Sugg, Chris [mailto:cgcsuggZn...]
> Sent: Monday, February 10, 2003 3:15 PM
> To: 'DoNotReply@consolut.eu'
> Subject: RE: SXC 1.54
>
>
> We have installed SXC 1.54 on our test exchange server and set up
an RFC
> connection in R/3, following the installation guide for the
software. We
> can
> ping and trace route the IP address and domain name from the
AS400's and
> the
> domain server but from the RFC connection Gateway, our 'Test
> Connection'
> fails in R/3 with:
>
> ERROR partner not reached (host xxxxxxxx.xxxxxxxx,
sevice
> sapgw00)
> LOCATION SAP-Gateway on host xxxxxxxx.xxxx.com /
sapgw01
> DETAIL
NiPConnect2
> CALL
SO_ERROR
> COMPONENT NI (network
interface)
> COUNTER
15347
> ERROR TEXT A remote host refused an attempted connect
> operation.
> ERROR NUMBER
3425
>
> I can see from SMGW the connections start, but the connection test
still
> fails. I have looked at the relevant notes in OSS for Exchange
> connectivity
> and everything seems to be in order. Does anyone have any
suggestions
> for us
> to try?
>
> Thanks,
> Chris Sugg
>
>
> Have a look to our homepage at: http://www.consolut.net
> DoNotReply@consolut.eu
>
> Your use of consolut is subject to
> http://www.consolut.net


Durban Tours - Südafrika Safari

Fill RESBD Structure from EBP Component Structure   Fill RESBD Structure from EBP Component Structure  
This documentation is copyright by SAP AG.

Length: 4972 Date: 20240425 Time: 085730     sap01-206 ( 2 ms )