09912 - FW: BW upgrade to 31C; CRTSHDINST command fails

09912 - FW: BW upgrade to 31C; CRTSHDINST command fails

ABAP Short Reference   BAL_S_LOG - Application Log: Log header data  
This documentation is copyright by SAP AG.
SAP E-Book

FW: BW upgrade to 31C; CRTSHDINST command fails

Hi Tom,

I have recently upgraded my BW system from 2.1 to 3.1
and it was successful. I see that you patched the R3UP
library. You also need to patch the R3620opt (i.e. 620
kernel library) with the latest stopsap, startsap,
crtshdinst, dltshdinst, TP and R3TRANS programs. Also
be shore to update your 4.6D kernel with the latest TP
and R3TRANS.

Also make sure that you have the FIX_BW310.SAR file in
the /usr/sap/put directory.

Cheers,
Strini
--- Rooyen Tom van <tvroZoce.nl> wrote:
> Hi Volker,
>
> The ticket is 329348
>
> regards,
>
> Tom
>
> -----Original Message-----
> From: Gueldenpfennig, Volker
> [mailto:volker.gueldenpfennigZsap.com]
> Sent: woensdag 23 april 2003 12:33
> To: 'DoNotReply@consolut.eu'
> Cc: 'tvroZoce.nl'
> Subject: RE: BW upgrade to 31C;
> CRTSHDINST command fails
>
>
> Hi Tom,
>
> I think, we need an OSS ticket here.
>
> Regards
>
> Volker
>
> -----Original Message-----
> From: Rooyen Tom van [mailto:tvroZoce.nl]
> Sent: Mittwoch, 23. April 2003 12:24
> To: 'DoNotReply@consolut.eu'
> Subject: BW upgrade to 31C;
> CRTSHDINST command fails
>
>
> Hi,
>
> We're doing an upgrade of BW 21C to BW 31C and are
> in the prepare phase.
> During the installation module the CRTSHDINST,
> create shadow instance, fails
> with : Failed to create R/3 instance. SAP0899
> message.
>
> The above message and the below log extracts are
> from the QP0ZSYSC spoolfile
> created by the process
>
> Also in the log:
>
> Message . . . . : Error on command CRTSHDINST
> SID(D70) INST(66).
>
> Cause . . . . . : The system detected an error
> when trying to run command
>
> CRTSHDINST SID(D70) INST(66). The message
> identifier received from the
>
> command was CEE9901. Recovery . . . : See the
> details of message
>
> identifier CEE9901 using the Display Message
> Description (DSPMSGD) command
>
> to determine the errors. Correct the errors and
> then try the command
> again.
>
> still further in the log:
>
> CPF24A3: Message . . . . : Value for call stack
> counter parameter not
> valid.
> Cause . . . . . : The value 5, specified for call
> stack counter parameter,
>
> is not valid. The value was specified in parameter
> number 7 on the API.
>
> Recovery . . . : Correct the value for call
> stack counter parameter and
>
> try the request again. This value must be greater
> than or equal to 0 but
>
> cannot be larger than the number of entries on the
> call stack.
>
>
> We have updated the CRTSHDINST executable per note
> 500297. We have also
> updated r3UP to 620-4 and R3TRANS and TP in R3UP.
> When we try to execute the command form the
> commandline it fails in the same
> way.
>
> Anyone an idea what this error is and how it can be
> solved (we have also
> opened an OSS ticket for this)
>
> Regards,
>
> Tom van Rooyen
>
>
> Have a look to our homepage at:
> http://www.consolut.net
>
> DoNotReply@consolut.eu
>
> Your use of consolut is subject to
> http://www.consolut.net
>


=====
Strini Mudaly
Tel : 781 354 1312

__________________________________________________
Do you consolut?
The New consolut Search - Faster. Easier. Bingo
http://search.consolut.net

Durban Tours - Südafrika Safari

CPI1466 during Backup   General Material Data  
This documentation is copyright by SAP AG.

Length: 5313 Date: 20240425 Time: 005714     sap01-206 ( 3 ms )