Hi Thomas,

Then I think that PTF SI10829 created the error, since this is the
only PTF we applied this weekend. We also deleted the SQL packages.

Agoes created an OSS message no 720929 with the problem.

Br,
Teddy Løv Andersen
ECCO Sko A/S, SAP Basis

--- In DoNotReply@consolut.eu, thomas.kremminZs... wrote:
>
> Hi,
> yes we did.
>
> 5722999-MF31271
>
> 5722SS1-SI10584 V5R2M0
> 5722SS1-SI10293 V5R2M0
> 5722SS1-SI10742 V5R2M0
> 5722SS1-SI10743 V5R2M0
> 5722SS1-SI10745 V5R2M0
> 5722SS1-SI10746 V5R2M0
> 5722SS1-SI10805 V5R2M0
> 5722SS1-SI10829 V5R2M0
>
> And we deleted the SQL Packages.
> early in the morning (at about 6:00 o'clock) evry thing went fine.
> The dumps started at about eight o'clock when every one starts
working.
>
>
>
> Best regards / Mit freundlichen Grüßen
>
> Thomas
>
>
>

> "tla_ecco"

>
<tlaZe...>
>
An
> 08.12.2003 11:18
DoNotReply@consolut.eu
>
Kopie
>

> Bitte
antworten Thema
> zu Antwort: Re:
SQL
> SAP on System iZyaho -
332
>
ogroups.com
>

>

>

>

>

>
>
>
>
> Hi Thomas,
>
> Did you apply any PTF during the weekend?
>
> Br,
> Teddy
> ECCO Sko A/S, SAP Basis
> --- In DoNotReply@consolut.eu, "Agoes B. Poerwanto" <abpZe...>
> wrote:
> >
> >
> >
> >
> > Hi Thomas,
> >
> > I also created an OSS message number 720929.
> >
> > Best regards,
> > Agoes
> >
> >
> >
> >
>
> >
> thomas.kremminZse
>
> > eber.de To:
> DoNotReply@consolut.eu
>
> >
> cc:
>
> > 08-12-03 09:43 AM Subject: Antwort:
> Re: SQL -332
> > Please respond
> to
>
> >
> SAP on System i
>
> >
>
> >
>
> >
> >
> >
> >
> >
> > Hi Agoes,
> >
> > this note is based on an ASCII database. We are working with
EBSDIC.
> > And its not only in query, as I've be told its all over the whole
> system.
> >
> >
> > Best regards / Mit freundlichen Grüßen
> >
> > Thomas
> >
> >
> >
> > "Agoes B.
> > Poerwanto"
> > <abpZe...>
> An
> >
DoNotReply@consolut.eu
> > 08.12.2003
> 09:38 Kopie
> >
> >
> Thema
> > Bitte antworten Re: SQL -332
> > zu
> > SAP on System iZyaho
> > ogroups.com
> >
> >
> >
> >
> >
> >
> >
> >
> >
> >
> >
> > Hi Thomas and group,
> >
> > I also have the same case in table M_VMVMA. When I searched in
OSS,
> I found
> > note 489212 'iSeries: SQL0332, "DBIF_RSQL_SQL_ERROR" runtime
> error'. It
> > happened when a user is pressing 'F4'. So you think it sloves the
> problem.
> >
> >
> > Best regards,
> > Agoes Boedi Poerwanto
> > SAP Basis
> > ECCO Sko A/S
> > Phone: +45 7491 1957
> > Mobile: +45 2373 1059
> > mailto:abpZe...
> >
> >
> >
> >
> > thomas.kremminZse
> >
> > eber.de To:
> > DoNotReply@consolut.eu
> >
> > cc:
> >
> > 08-12-03 09:26 AM Subject:
> SQL
> > -332
> > Please respond to
> >
> > SAP on System i
> >
> >
> >
> >
> >
> >
> >
> > Hi group,
> >
> > since this morning we have alot of SQL DUMPS.
> >
> > ***LOG BY4=> sql error -332 performing SEL on table TSP03A
> [dbtran
> > 7009 ]
> > ***LOG BY0=> Zeichenumsetzung zwischen CCSID 500 und CCSID 0 ung}
> ltig.
> > Job=190845/SEP02/WP02 [dbtran 7009 ]
> > dbtran ERROR LOG (hdl_dbsl_error): DbSl 'SEL'
> >
> >
> > Last night we installed this IBM PTF'S:
> >
> > Anlegen der PTF gestartet.
> > Vorläufige Fehlerbehebung (PTF) 5722999-MF31271 V5R2M0 in B
> > Anlegen der PTFs für Produkt 5722999 erfolgreich beendet.
> > Vorläufige Fehlerbehebung (PTF) 5722SS1-SI10584 V5R2M0 in B
> > Vorläufige Fehlerbehebung (PTF) 5722SS1-SI10293 V5R2M0 in B
> > Vorläufige Fehlerbehebung (PTF) 5722SS1-SI10742 V5R2M0 in B
> > Vorläufige Fehlerbehebung (PTF) 5722SS1-SI10743 V5R2M0 in B
> > Vorläufige Fehlerbehebung (PTF) 5722SS1-SI10745 V5R2M0 in B
> > Vorläufige Fehlerbehebung (PTF) 5722SS1-SI10746 V5R2M0 in B
> > Vorläufige Fehlerbehebung (PTF) 5722SS1-SI10805 V5R2M0 in B
> > Vorläufige Fehlerbehebung (PTF) 5722SS1-SI10829 V5R2M0 in B
> > Anlegen der PTFs für Produkt 5722SS1 erfolgreich beendet.
> > Anlegen der PTFs beendet.
> > PTFs beim IPL angelegt oder entfernt.
> >
> > I opend an OSS ticket. 002007974700005470902003
> >
> > But perhaps someone of you had the problem before and know a
> solution.
> >
> >
> > Best regards / Mit freundlichen Grüßen
> >
> > Thomas
> >
> >
> >
> >
> > Have a look to our homepage at: http://www.consolut.net
> > DoNotReply@consolut.eu
> >
> > Your use of consolut is subject to
> http://www.consolut.net
> >
> >
> >
> >
> >
> > consolut Sponsor
> >
> >
> >
> >
> >
> >
> >
> >
> >
> >
> >
> >
> > Have a look to our homepage at: http://www.consolut.net
> > DoNotReply@consolut.eu
> >
> > Your use of consolut is subject to the consolut Terms of
Service.
> >
> >
> >
> >
> >
> > Have a look to our homepage at: http://www.consolut.net
> > DoNotReply@consolut.eu
> >
> > Your use of consolut is subject to
> http://www.consolut.net
>
>