CPA2610 - Device &1 cannot be varied off at this time. (C G) ( OS/400 )
General Material Data Vendor Master (General Section)This documentation is copyright by IBM.
Message : CPA2610
Device &1 cannot be varied off at this time. (C G)
Message Long Text :
Cause . . . . . : There are jobs in the system that are currently using device &1.
Recovery . . . : Use the Work with Configuration Status (WRKCFGSTS) command to determine which jobs are using the device.
Type G to vary off device &1 with active jobs.
Type C to either wait for the jobs to complete before you try to vary the device off again or end the jobs yourself and vary off the device.
Possible choices for replying to message . . . . . . . . . . . . . . . :
G -- vary off device with active jobs
C -- wait to vary off device later when jobs have ended
Message File : QCPFMSG
Library Message File : QSYS2924