CPA5719 - Controller &24 not contacted. Configuration problem. (C R) ( OS/400 )

CPA5719 - Controller &24 not contacted. Configuration problem. (C R) ( OS/400 )

TXBHW - Original Tax Base Amount in Local Currency   BAL_S_LOG - Application Log: Log header data  
This documentation is copyright by IBM.
SAP E-Book


Message : CPA5719
Controller &24 not contacted. Configuration problem. (C R)

Message Long Text :

Cause . . . . . : The station address that is being used during exchange identifier (XID) processing is not the same as the station address (STNADR parameter) that is specified in the controller description. The probable causes are:
-- The remote system is sending the wrong station address.
-- The local or remote station address specified in the controller description is not correct.
-- The line description being used has a data link role of either secondary (*SEC) or negotiable (*NEG). The station address (STNADR parameter) specified in the line description is not the same as the STNADR specified in the controller description.
Recovery . . . : Use the Work with Line Description (WRKLIND) command and the Work with Controller Description (WRKCTLD) command to verify that the station address specified in both the line description and the controller description agrees. Also, verify the station address agrees with the remote system.
If the data link role parameter is specified as secondary (*SEC) or negotiable (*NEG), the station address being used during XID processing must be the same as the STNADR parameter specified in the line description.
If the data link role parameter has been specified as primary (*PRI) in the line description, the station address being used during XID processing must be the same as the remote system station address.
Then do one of the following:
-- Type C to cancel recovery and to inform any applications that are waiting for an operation that the recovery has been canceled.
-- Type R to try the operation one more time.
If the problem continues, report the problem (ANZPRB command).
Possible choices for replying to message . . . . . . . . . . . . . . . :
C -- Cancel.
R -- Try again one more time.
Technical description . . . . . . . . : The station address is &41. The error code is &40: The station address being used during XID processing is not the same as the STNADR specified in the controller description.
The received XID matched either the exchange identifier (EXCHID parameter) or the remote network identifier (RMTNETID parameter) and remote control point name (RMTCPNAME parameter) in the controller description.
For more information on XIDs, see Systems Network Architecture Formats, GA27-3136.

Message File : QCPFMSG
Library Message File : QSYS2924