Ansicht
Dokumentation
CPA575B - Controller &24 on line &23 not contacted. Probable configuration problem. (C R) ( OS/400 )
PERFORM Short Reference RFUMSV00 - Advance Return for Tax on Sales/PurchasesThis documentation is copyright by IBM.
Message : CPA575B
Controller &24 on line &23 not contacted. Probable configuration problem. (C R)
Message Long Text :
Cause . . . . . : The controller may not be configured correctly, or the remote system may be failing.
Recovery . . . : Make sure that the controller type (TYPE parameter) in the controller description is correct for the remote system. If it is not correct, then make the necessary changes. If it is correct, contact the remote system operator to determine if any problem exists on the remote system that could cause this problem.
Then do one of the following:
-- Type C to cancel recovery and to inform any applications that are waiting for an operation that the recovery has been canceled.
-- Type R to try the operation one more time.
If the problem continues, report the problem (ANZPRB command).
Possible choices for replying to message . . . . . . . . . . . . . . . :
C -- Cancel.
R -- Try again one more time.
Technical description . . . . . . . . :
The error code is &40: A Systems Network Architecture (SNA) negative response was received in reply to an SNA ACTPU command that was sent by the local system. If the TYPE parameter of the controller description is correct, contact the remote system operator to determine why the remote system sent the negative response to the ACTPU.
Message File : QCPFMSG
Library Message File : QSYS2924
General Material Data SUBST_MERGE_LIST - merge external lists to one complete list with #if... logic for R3up
This documentation is copyright by IBM.
Length: 3280 Date: 20240419 Time: 094722 sap01-206 ( 2 ms )