Ansicht
Dokumentation

CPA57A0 - Network interface &30 failed. Unable to detect power source from NT. (C G R) ( OS/400 )

CPA57A0 - Network interface &30 failed. Unable to detect power source from NT. (C G R) ( OS/400 )

Addresses (Business Address Services)   ROGBILLS - Synchronize billing plans  
This documentation is copyright by IBM.
SAP E-Book


Message : CPA57A0
Network interface &30 failed. Unable to detect power source from NT. (C G R)

Message Long Text :

Cause . . . . . : The system has been unable to detect the power source from the NT. The NT or connection to the NT may have failed, or the network interface may not be correctly configured.
Recovery . . . : Verify the operation of the NT and the connection. Verify the proper network type (NETTYPE) was specified for the network interface description. Reply to the message.
If the problem continues, press F14 to run problem analysis.
Possible choices for replying to message . . . . . . . . . . . . . . . :
C -- Cancel recovery and inform any applications and subsystems that are waiting for an operation that the recovery has been canceled.
G -- Start the automatic communications recovery again as defined by the communications recovery limit (CMNRCYLMT) configured for network interface &30.
R -- Try again one more time.
Technical description . . . . . . . . : The error log identifier is &22.
The error code is &40: The system was unable to detect Power Source 1 (PS1) from the NT during activation of the physical interface. Physical line sync was established, however.

Message File : QCPFMSG
Library Message File : QSYS2924


PERFORM Short Reference   TXBHW - Original Tax Base Amount in Local Currency  
This documentation is copyright by IBM.

Length: 3274 Date: 20240420 Time: 150547     sap01-206 ( 2 ms )