Message : CPA596C
Line &23 failed. Probable local hardware problem. (C G R)

Message Long Text :

Cause . . . . . : The probable causes are:
-- A local hardware problem.
-- A local DCE problem.
-- A line problem.
Recovery . . . : Do one of the following:
-- Type C to cancel recovery and to inform any applications that are waiting for an operation that the recovery has been canceled.
-- Type G to start the automatic communications recovery again as defined by the system communications recovery limit (CMNRCYLMT) for line &23.
-- Type R to try the operation one more time.
If the problem continues, press F14 to run problem analysis.
Possible choices for replying to message . . . . . . . . . . . . . . . :
C -- Cancel.
G -- Start automatic recovery again.
R -- Try again one more time.
Technical description . . . . . . . . : The error log identifier is &22.
The error code is &40: A path error occurred during a communications session. The error codes and their meanings are as follows:
54001A00 -- A direct memory access receive error occurred.
54001A01 -- A direct memory access transmit error occurred.
54001A02 -- Either an interrupt occurred that was not expected or not valid, or an interrupt that was not enabled occurred.
54001010 -- Input/output processor resource limitations.

Message File : QCPFMSG