CPA59D3 - Line &23 failed. HDLC data link not active. (C G R) ( OS/400 )
rdisp/max_wprun_time - Maximum work process run time ROGBILLS - Synchronize billing plansThis documentation is copyright by IBM.
Message : CPA59D3
Line &23 failed. HDLC data link not active. (C G R)
Message Long Text :
Cause . . . . . : The local system attempted to perform a packet level operation. However, the high-level data link control (HDLC) data link was no longer active. This is probably due to one of the following:
-- An X.25 network problem.
-- A local system problem.
Recovery . . . : Verify that the X.25 network is functioning properly, and do one of the following:
-- Type C to cancel recovery and to inform any applications that are waiting for an operation that the recovery has been canceled.
-- Type G to start the automatic communications recovery again as defined by the system communications recovery limit (CMNRCYLMT) for line &23.
-- Type R to try the operation one more time.
If the problem continues, report the problem (ANZPRB command).
Possible choices for replying to message . . . . . . . . . . . . . . . :
C -- Cancel.
G -- Start automatic recovery again.
R -- Try again one more time.
Technical description . . . . . . . . : The error log identifier is &22.
The error code is &40: An open request was rejected because link was no longer ready (probably due to HDLC link failure).