Ansicht
Dokumentation
CPC1210 - Prestart job ending due to maximum use. ( OS/400 )
Addresses (Business Address Services) rdisp/max_wprun_time - Maximum work process run timeThis documentation is copyright by IBM.
Message : CPC1210
Prestart job ending due to maximum use.
Message Long Text :
Cause . . . . . : The number of program start requests that the prestart job handled was the maximum defined by the MAXUSE parameter on the prestart job entry in the subsystem description.
Recovery . . . : The MAXUSE value can be changed by the Change Prestart Job Entry (CHGPJE) command if needed.
Message File : QCPFMSG
Library Message File : QSYS2924
CPI1466 during Backup Fill RESBD Structure from EBP Component Structure
This documentation is copyright by IBM.
Length: 3221 Date: 20240425 Time: 064158 sap01-206 ( 2 ms )