Ansicht
Dokumentation

CPD2621 - Controller &1 not compatible with its attachments. ( OS/400 )

CPD2621 - Controller &1 not compatible with its attachments. ( OS/400 )

ABAP Short Reference   BAL_S_LOG - Application Log: Log header data  
This documentation is copyright by IBM.
SAP E-Book


Message : CPD2621
Controller &1 not compatible with its attachments.

Message Long Text :

Cause . . . . . : The controller description &1 is not created. Reason code is &2. Reason codes have these meanings:
1201 -- The attached nonswitched line (LINE parameter) or an attached device (DEV parameter) cannot attach to this controller description.
1202 -- An attached device (DEV parameter) is currently attached to another controller description.
1203 -- Duplicate attached device (DEV parameter).
1204 -- Either an attached device (DEV parameter) is not compatible with this controller, or the attached nonswitched line (LINE parameter):
- Is wrong line type.
- Is a switched line.
- Has wrong role.
- Is point-to-point and has a controller attached.
- Is a secondary line with a primary controller attached.
- Already has its maximum number of controllers attached.
- Does not have a logical channel entry (LGLCHLE parameter) matching the logical channel ID (LGLCHLID parameter).
1205 -- Attached devices (DEV parameter) have duplicate addresses.
1206 -- Line in switched line list (SWTLINLST parameter):
- Is wrong line type.
- Is nonswitched without switched network backup.
- Has wrong role.
1207 -- Attached devices (DEV parameter) have the same value specified for both local and remote location names (LCLLOCNAME and RMTLOCNAME parameters), and the same value specified for both the remote network identifier (RMTNETID parameter) and the local network ID network attribute. For virtual APPN controllers, a device with the same local and remote location names and the same value for both the remote network identifier and the local network identifier is already attached to a virtual APPN controller.
1208 -- Attached devices (DEV parameter) have addresses outside valid range for this controller.
1209 -- Attached devices (DEV parameter) are not APPN-capable, and this controller is APPN-capable, or attached devices (DEV parameter) are APPN-capable, and this controller is not APPN-capable. Devices attached to an APPC controller with link type (LINKTYPE parameter) *VRTAPPN must be APPN capable (APPN parameter).
1210 -- Attached controller (CTL parameter) is local and the device is virtual, or attached controller is virtual and the device is local.
0108 -- An internal operation failed to complete. Try the request again.
Recovery . . . : Correct any errors, then try the request again.

Message File : QCPFMSG
Library Message File : QSYS2924


SUBST_MERGE_LIST - merge external lists to one complete list with #if... logic for R3up   General Material Data  
This documentation is copyright by IBM.

Length: 3274 Date: 20240420 Time: 052434     sap01-206 ( 2 ms )