Ansicht
Dokumentation

CPD2658 - Device &25 reset failed. ( OS/400 )

CPD2658 - Device &25 reset failed. ( OS/400 )

BAL Application Log Documentation   CL_GUI_FRONTEND_SERVICES - Frontend Services  
This documentation is copyright by IBM.
SAP E-Book


Message : CPD2658
Device &25 reset failed.

Message Long Text :

Cause . . . . . : An input/output processor (IOP) reset failed when varying on device &25. Reason code is &1. Reset failed for one of the following reasons:
--00002010: IOP has a disk attached.
--00002011: IOP is in use by object &31 type &32. If the object name and type are blanks, either the resource is in use by the Dedicated Service Tools (DST), another client, or the data is not available.
--00002012: Time-out or error occurred while attempting reset. If the machine storage pool size is set to a value close to the reserved pool size, an IOP reset may fail because not enough memory is available.
Recovery . . . : Reason codes and their recoveries follow. Do one of the following and then try the request again:
--00002010: Do an initial program load (IPL). Vary on device &25. If the problem continues, report the problem (ANZPRB command).
--00002011: Vary off the object associated with the IOP to be reset with the Vary Configuration (VRYCFG) command or deallocate the resource.
--00002012: Use the Work with System Status (WRKSYSSTS) command to increase the size of the machine storage pool. See the Work management topic collection in the Systems management category in the IBM i Information Center book, http://www.ibm.com/systems/i/infocenter/, for information about using this command. If the problem continues, do an initial program load (IPL). Vary on device &25. If the IPL does not correct the problem, report the problem (ANZPRB command).

Message File : QCPFMSG
Library Message File : QSYS2924