Ansicht
Dokumentation

CPD2691 - Controller &24 vary failed. Reset required. ( OS/400 )

CPD2691 - Controller &24 vary failed. Reset required. ( OS/400 )

rdisp/max_wprun_time - Maximum work process run time   RFUMSV00 - Advance Return for Tax on Sales/Purchases  
This documentation is copyright by IBM.
SAP E-Book


Message : CPD2691
Controller &24 vary failed. Reset required.

Message Long Text :

Cause . . . . . : Either the power is not turned on for the card enclosure with the input/output processor (IOP) or an error occurred that requires an IOP reset.
Recovery . . . : Verify that the card enclosure has power. If the card enclosure has power, vary on controller &24 (VRYCFG command), specifying *YES for the RESET parameter. Use F10 (additional parameters) on the prompt display to change the RESET parameter.
If the problem continues, display the QSYSOPR message queue (DSPMSG command). If the controller specifies a message queue (MSGQ parameter) other than QSYSOPR, display the messages in the specified message queue. Look for messages at the beginning of the message queue that indicate equipment was removed or failed, and do the recovery action specified in those messages.
If the problem continues, report the problem (ANZPRB command) specifying the system machine type and serial number.
Technical description . . . . . . . . : Reason code &1. Reason codes and their meanings follow:
--00002001: IOP is not usable.
--00002005: IOP is not operational.
--0000200F: Error with controller description object.

Message File : QCPFMSG
Library Message File : QSYS2924


rdisp/max_wprun_time - Maximum work process run time   Addresses (Business Address Services)  
This documentation is copyright by IBM.

Length: 3238 Date: 20240328 Time: 104931     sap01-206 ( 3 ms )