Ansicht
Dokumentation
CPD26C9 - Emulation parameters not valid for application type. ( OS/400 )
Vendor Master (General Section) Fill RESBD Structure from EBP Component StructureThis documentation is copyright by IBM.
Message : CPD26C9
Emulation parameters not valid for application type.
Message Long Text :
Cause . . . . . : At least one emulation parameter (EMLDEV, EMLKBD, EMLNUMLCK, or EMLWRKSTN) was specified, but 3270 emulation (*EML) was not specified as the application type (APPTYPE parameter).
Recovery . . . : Remove any emulation parameters (EMLDEV, EMLKBD, EMLNUMLCK, or EMLWRKSTN) if this is not 3270 emulation. If this is to be 3270 emulation then change the application type to *EML. Then try the request again.
Message File : QCPFMSG
Library Message File : QSYS2924
Addresses (Business Address Services) General Data in Customer Master
This documentation is copyright by IBM.
Length: 3234 Date: 20240329 Time: 150855 sap01-206 ( 3 ms )