CPD2741 - Controller &1 not compatible with attachments. ( OS/400 )

CPD2741 - Controller &1 not compatible with attachments. ( OS/400 )

Addresses (Business Address Services)   General Material Data  
This documentation is copyright by IBM.
SAP E-Book


Message : CPD2741
Controller &1 not compatible with attachments.

Message Long Text :

Cause . . . . . : The controller description &1 is not created. Reason code is &2. Reason codes and their meanings follow:
1211 -- Attached devices (DEV parameter) have a value that is not valid for maximum length of request unit; the value must be a multiple of 256 or *CALC. Other values may only be used for X.25 connections.
1213 -- X.25 default receive packet size (DFTPKTSIZE parameter) on the controller is larger than the maximum receive packet size (MAXPKTSIZE parameter) of the attached nonswitched line (LINE parameter).
1214 -- Maximum frame size (MAXFRAME parameter) is larger than the MAXFRAME value of the attached nonswitched line.
1216 -- X.25 default receive window size (DFTWDWSIZE parameter) on the controller is not compatible with the modulus (MODULUS parameter) of the attached nonswitched line (LINE parameter).
1217 -- Lines specified in the switched line list (SWTLINLST parameter) do not have matching APPN parameters.
1218 -- No model Axx tape device is attached to the tape controller.
1219 -- More than one model Axx tape device is attached to the tape controller.
1220 -- Only one network controller can be attached to a line.
1226 -- All attached lines for short-hold mode connections must specify the same APPN node type (NODETYPE parameter).
1228 -- For short-hold mode connections, local location address 00 (LOCADR parameter) cannot be specified for devices attached to SNA host controllers.
1230 -- An attached device has a port number (PORT parameter) outside the valid range for this controller. For 2638 controllers, port 0 and port 1 are valid. For 2637 controllers, ports 0 through 5 are valid.
1231 -- Shared session number (SHRSSNNBR) is not valid for the device that is being attached to this controller. The value must be 0 when the controller is not a 5494, 2661, or 6050.
1261 -- The X.25 default transmit packet size (DFTPKTSIZE parameter) on the controller description is greater than the maximum transmit packet size (MAXPKTSIZE parameter) on the line description.
1262 -- X.25 default transmit window size (DFTWDWSIZE parameter) on the controller description is not compatible with the modulus (MODULUS parameter) of the attached nonswitched line (LINE parameter).
Recovery . . . : Correct any errors, then try the request again.