Ansicht
Dokumentation

CPD276E - Controller &1 vary processing stopped. ( OS/400 )

CPD276E - Controller &1 vary processing stopped. ( OS/400 )

BAL_S_LOG - Application Log: Log header data   rdisp/max_wprun_time - Maximum work process run time  
This documentation is copyright by IBM.
SAP E-Book


Message : CPD276E
Controller &1 vary processing stopped.

Message Long Text :

Cause . . . . . : Controller &1 has one or more attached device descriptions that are damaged. No attached device descriptions can be processed.
Recovery . . . : Display the status of controller &1 and its attached device descriptions using the Work with Configuration Status (WRKCFGSTS) command.
If the status of the device descriptions is displayed:
1) Delete the damaged device descriptions attached to controller description &1 (DLTDEVD command).
2) Create the device descriptions using the appropriate create device description command and attach the device descriptions to controller description &1.
If the status of the device descriptions is not displayed:
1) Delete controller description &1 (DLTCTLD command).
2) Create controller description &1 using the appropriate create controller description command and attach all the device descriptions to controller description &1. An error message will indicate which device description is damaged.
1) Delete the damaged device descriptions (DLTDEVD command).
2) Create device descriptions using the appropriate create device description command and attach the device descriptions to controller description &1.

Message File : QCPFMSG
Library Message File : QSYS2924


ABAP Short Reference   General Data in Customer Master  
This documentation is copyright by IBM.

Length: 3236 Date: 20240425 Time: 230947     sap01-206 ( 3 ms )