Ansicht
Dokumentation
CPD27D2 - Device &25 vary on failed. ( OS/400 )
General Data in Customer Master Addresses (Business Address Services)This documentation is copyright by IBM.
Message : CPD27D2
Device &25 vary on failed.
Message Long Text :
Cause . . . . . : The device resource is currently in use by object &31 type &32. If the object name and type are blanks, either the resource is in use by the Dedicated Service Tools (DST), another client, or the data is not available.
If a media library drive is being allocated, the drive may already be allocated to another media library device that is varied on.
Recovery . . . : Do one of the following:
-- Vary off the active device and vary on device &25.
-- Use the active device instead of device &25.
-- Deallocate the device on Network Server &31.
-- Vary off the active media library device, or deallocate the drive from the active media library device.
-- Change the resource name specified for device description &25 to correspond to a resource that does not have a varied on device.
-- On the console device from the Work with DST Environment display, cancel the device operation and deallocate the device. This display can be obtained in three ways:
- If an initial program load (IPL) was not done in DST debug mode, select F21 on the operator panel.
- If an IPL was done in DST debug mode, press system request and type "DST".
- From the system IPL sign on display, select the option to access DST.
Message File : QCPFMSG
Library Message File : QSYS2924
General Material Data CL_GUI_FRONTEND_SERVICES - Frontend Services
This documentation is copyright by IBM.