CPD27D7 - Inactivity timer cannot be specified. ( OS/400 )
Addresses (Business Address Services) ROGBILLS - Synchronize billing plansThis documentation is copyright by IBM.
Message : CPD27D7
Inactivity timer cannot be specified.
Message Long Text :
Cause . . . . . : The inactivity timer (INACTTMR parameter) can only be specified if one of the following conditions exists:
-- The device class (DEVCLS parameter) is *LCL and the device type (TYPE parameter) is ASCII.
-- The device class (DEVCLS parameter) is *SNPT.
-- The device class (DEVCLS parameter) is *LAN and the Advanced Function Printing (AFP parameter) is *NO.
-- The application type (APPTYPE parameter) is *NRF.
-- The application type (APPTYPE parameter) is *CTLSSN, *DEVINIT, or *APPINIT.
Recovery . . . : Remove the value specified for the inactivity timer (INACTTMR parameter), then try the request again.