Ansicht
Dokumentation

CPD2899 - Maximum length request unit value not valid. ( OS/400 )

CPD2899 - Maximum length request unit value not valid. ( OS/400 )

General Material Data   CL_GUI_FRONTEND_SERVICES - Frontend Services  
This documentation is copyright by IBM.
SAP E-Book


Message : CPD2899
Maximum length request unit value not valid.

Message Long Text :

Cause . . . . . : The maximum length request unit (MAXLENRU parameter) value specified is not valid for local location address (LOCADR parameter) 01. The maximum length request unit value specified for a device with location address 01 must be 247 or 256. Specify 247 if the device is connected to the system using an X.25 network.
Recovery . . . : Change the maximum length request unit to 247 or 256, or change the local location address to some value other than 01, then try the request again.

Message File : QCPFMSG
Library Message File : QSYS2924


SUBST_MERGE_LIST - merge external lists to one complete list with #if... logic for R3up   General Material Data  
This documentation is copyright by IBM.

Length: 3226 Date: 20240424 Time: 023114     sap01-206 ( 2 ms )