CPD28E0 - X.25 switched line selection not allowed. ( OS/400 )
SUBST_MERGE_LIST - merge external lists to one complete list with #if... logic for R3up General Data in Customer MasterThis documentation is copyright by IBM.
Message : CPD28E0
X.25 switched line selection not allowed.
Message Long Text :
Cause . . . . . : The X.25 switched line selection (SWTLINSLCT parameter) can be specified only if the link type (LINKTYPE parameter) is X.25 (*X25) and the controller is switched (SWITCHED parameter).
Recovery . . . : Remove the value specified for the X.25 switched line selection, then try the request again.
Message File : QCPFMSG
Library Message File : QSYS2924