CPD3011 - File attribute &2 not valid with SYSTEM(*RMT). ( OS/400 )
rdisp/max_wprun_time - Maximum work process run time PERFORM Short ReferenceThis documentation is copyright by IBM.
Message : CPD3011
File attribute &2 not valid with SYSTEM(*RMT).
Message Long Text :
Cause . . . . . : The value &2, specified on the file attribute (FILEATR) parameter, is not allowed with remote system processing (SYSTEM(*RMT)). The only file attribute values allowed with remote system processing are *ALL, *LF, or *PF.
Recovery . . . : Do one of the following, and then try the request again:
-- Change the SYSTEM parameter to *ALL or *LCL.
-- Change the FILEATR parameter to *ALL, *LF, or *PF.
Message File : QCPFMSG
Library Message File : QSYS2924