CPD3209 - MAINT or FRCACCPTH not valid for file &1. ( OS/400 )

CPD3209 - MAINT or FRCACCPTH not valid for file &1. ( OS/400 )

Fill RESBD Structure from EBP Component Structure   General Material Data  
This documentation is copyright by IBM.
SAP E-Book


Message : CPD3209
MAINT or FRCACCPTH not valid for file &1.

Message Long Text :

Cause . . . . . : Either the MAINT(*REBLD) parameter or the FRCACCPTH(*YES) parameter was specified and is not valid because the access paths for file &1 in library &2 are being journaled. Files with journaled access paths must have either an immediate-access-path maintenance or a delayed-access-path maintenance specified on the MAINT parameter. These files must not be forcing changes made to the access paths with the FRCACCPTH parameter.
Recovery . . . : Remove either the MAINT(*REBLD) parameter or the FRCACCPTH(*YES) parameter and try the request again.

Message File : QCPFMSG
Library Message File : QSYS2924


General Data in Customer Master   SUBST_MERGE_LIST - merge external lists to one complete list with #if... logic for R3up  
This documentation is copyright by IBM.