Ansicht
Dokumentation
CPD3B5B - Sending of error indication for conversation &1 not complete. &14 ( OS/400 )
PERFORM Short Reference PERFORM Short ReferenceThis documentation is copyright by IBM.
Message : CPD3B5B
Sending of error indication for conversation &1 not complete. &14
Message Long Text :
Cause . . . . . : The system tried to send an error indicator and an end of conversation indicator to end the conversation because the program ended without ending the conversation. (Normally programs end the conversation before the programs end). However, the error indicator could not be sent because the remote program either continued to send data or did not respond within 30 seconds. The conversation with the remote program ended abnormally.
Recovery . . . : Check the program logic in the local program. Verify that the program should end before ending the conversation. If the program is using commitment control and rollback is required, the logical unit of work must be rolled back. Use the rollback operation to roll back any pending changes made since the last commitment boundary.
Message File : QCPFMSG
Library Message File : QSYS2924
rdisp/max_wprun_time - Maximum work process run time ROGBILLS - Synchronize billing plans
This documentation is copyright by IBM.