Message : CPD706A
Format of output file &1 in library &2 not valid, reason code &3.

Message Long Text :

Cause . . . . . : The format of the specified output file &1 does not match the required format based on the specified ENTDTALEN and NULLINDLEN parameter values. The reason codes and their meanings follow:
1 -- Number of fields in file &1 and model output file do not match.
2 -- File &1 and model output file differ in length, type or buffer position of one or more fields preceding the Null Value Indicators (NVI) and Entry Specific Data (ESD) fields.
3 -- OUTFILFMT(*TYPE1 or *TYPE2) was specified. If ENTDTALEN(*OUTFILFMT) was specified, then file &1 ESD is not a character field. If ENTDTALEN(*CALC) or a field length on the ENTDTALEN parameter was specified, either file &1 ESD is not a character field, or length of file &1 ESD does not match the length calculated by the system or specified on the ENTDTALEN parameter.
4 -- OUTFILFMT(*TYPE3, *TYPE4 or *TYPE5) was specified. If NULLINDLEN(*OUTFILFMT) was specified, file &1 NVI is not a character field. Otherwise, the type, data format or length of file &1 NVI does not match what is specified for the NULLINDLEN parameter.
5 -- OUTFILFMT(*TYPE3, *TYPE4 or *TYPE5) was specified. If ENTDTALEN(*OUTFILFMT) was specified, file &1 ESD is not a character field. Otherwise, the type, data format or length of file &1 ESD does not match what is specified for the ENTDTALEN parameter.
Output file processing continued.
If OUTFILFMT(*TYPE1 or *TYPE2) was specified, the format of the journal entries written to file &1 will match the format of the corresponding model output file for all fields up to ESD. The length of the ESD field is the record length of file &1 minus the lengths of all preceding fields.
If OUTFILFMT(*TYPE3, *TYPE4 or *TYPE5) was specified, the format of the journal entries written to file &1 will match the format of the corresponding model output file for all fields up to NVI. The value specified on the NULLINDLEN parameter determines the length and data format of the NVI field. The value specified on the ENTDTALEN parameter determines the data format of ESD. The length of the ESD field is the record length of file &1 minus the lengths of all preceding fields.
Recovery . . . : Either specify an output file that matches the corresponding model output file and the values specified on the ENTDTALEN and NULLINDLEN parameters, or specify an output file that does not previously exist. Then try the request again.

Message File : QCPFMSG