CPD7889 - End location too large. ( OS/400 )
ROGBILLS - Synchronize billing plans Vendor Master (General Section)This documentation is copyright by IBM.
Message : CPD7889
End location too large.
Message Long Text :
Cause . . . . . : The end location must be less than or equal to the display size. For a window record, the end location must be less than or equal to the window size minus one line. The value on the SLNO keyword, the starting location, and the length of the field are used to determine the end location.
Recovery . . . : Do one of the following, then try the request again.
-- Change the value of SLNO keyword
-- Change the starting location
-- Change the field length
-- If this is a window record, change the window-lines parameter on the WINDOW keyword.
Message File : QCPFMSG
Library Message File : QSYS2924
rdisp/max_wprun_time - Maximum work process run time CPI1466 during Backup