Ansicht
Dokumentation

CPD7952 - Only one key field allowed in source file. ( OS/400 )

CPD7952 - Only one key field allowed in source file. ( OS/400 )

Addresses (Business Address Services)   Vendor Master (General Section)  
This documentation is copyright by IBM.
SAP E-Book


Message : CPD7952
Only one key field allowed in source file.

Message Long Text :

Cause . . . . . : In a source file (FILETYPE(*SRC) specified on the command used to create the file), only the first field (sequence number) can be specified as the key field.
Recovery . . . : Either omit all the key fields except the key field for the first field in the record format and then try the request again, or specify FILETYPE(*DATA) on the command used to create the file.

Message File : QCPFMSG
Library Message File : QSYS2924


Vendor Master (General Section)   General Data in Customer Master  
This documentation is copyright by IBM.

Length: 3224 Date: 20240329 Time: 120910     sap01-206 ( 3 ms )