Ansicht
Dokumentation

CPD8284 - Data length specified not correct. ( OS/400 )

CPD8284 - Data length specified not correct. ( OS/400 )

BAL_S_LOG - Application Log: Log header data   ROGBILLS - Synchronize billing plans  
This documentation is copyright by IBM.
SAP E-Book


Message : CPD8284
Data length specified not correct.

Message Long Text :

Cause . . . . . : The data length sent as a parameter to &2 cannot be used with data type &1.
Recovery . . . : Specify one of the following data lengths and then try the request again:
-- For data type 0 or 6 specify a data length from 1-512 bytes.
-- For data type 2 specify a data length from 2-512 bytes.
-- For data type 3 specify a data length from 3-512 bytes.
-- For data type 1, 4, or 5 the data length field can be any valid packed decimal (15 5) because the data stream length is predetermined and will be set by the requested program.

Message File : QCPFMSG
Library Message File : QSYS2924


ROGBILLS - Synchronize billing plans   Fill RESBD Structure from EBP Component Structure  