Message : CPD8E97
Connection list entry not allowed.
Message Long Text :
Cause . . . . . : The connection list entry (CNNLSTOUTE parameter) can be specified only if the link type (LINKTYPE parameter) is IDLC (*IDLC), the switched connection (SWITCHED parameter) is *YES, and the initial connection (INLCNN parameter) is *DIAL.
Recovery . . . : Remove the value specified for the connection list entry, then try the request again.
Message File : QCPFMSG
Library Message File : QSYS2924