Ansicht
Dokumentation

CPD8EDA - Line description &1 not compatible with NWI. ( OS/400 )

CPD8EDA - Line description &1 not compatible with NWI. ( OS/400 )

PERFORM Short Reference   Addresses (Business Address Services)  
This documentation is copyright by IBM.
SAP E-Book


Message : CPD8EDA
Line description &1 not compatible with NWI.

Message Long Text :

Cause . . . . . : The change line description command failed. The reason code is &2. Reason codes and their meanings follow:
2134 -- The channel number (NWICHLNBR parameter) specified for the nonswitched line description is in use by another line description.
2135 -- The connection type (CNN parameter) of nonswitched (*NONSWT) specified for the line description does not match the connection type specified for the network interface description channel.
2144 -- The switched channel number (SWTNWILST parameter) specified for the switched line description is in use by another line description.
2145 -- The connection type (CNN parameter) of switched (*SWT) specified for the line description does not match the connection type specified for the network interface description channel.
2148 -- IDLC or X.25 line descriptions cannot be attached to a network interface (SWTNWILST parameter) that specifies third party (*THIRD) call control (CALLCTL parameter).
Recovery . . . : Correct any errors, then try the request again.

Message File : QCPFMSG
Library Message File : QSYS2924


General Material Data   Addresses (Business Address Services)  
This documentation is copyright by IBM.

Length: 3236 Date: 20240425 Time: 031950     sap01-206 ( 4 ms )