Message : CPD8EE1
Workstation customizing object is not allowed.

Message Long Text :

Cause . . . . . : The workstation customizing object (WSCST parameter) can be specified for display devices only if the device class (DEVCLS parameter) is local (*LCL) or remote (*RMT). WSCST is not valid for 5555 displays or models 1 and 2 of 5150. For printer devices the workstation customizing object (WSCST parameter) can be specified only for ASCII printers or printers for which the host print transform function (TRANSFORM parameter) has been enabled.
Recovery . . . : Remove the value specified for the workstation customizing object, then try the request again.