Ansicht
Dokumentation
CPD8F3B - One or more parameters not valid for resource name. ( OS/400 )
Fill RESBD Structure from EBP Component Structure CL_GUI_FRONTEND_SERVICES - Frontend ServicesThis documentation is copyright by IBM.
Message : CPD8F3B
One or more parameters not valid for resource name.
Message Long Text :
Cause . . . . . : When the line being configured is attached to the network via a frame relay network interface (resource name is *NWID and network interface type is *FR), the following parameters must be specified as shown below:
Activate LAN manager (ACTLANMGR) -- *YES
TRLAN manager logging level (TRNLOGLVL) -- *OFF
TRLAN manager mode (TRNMGRMODE) -- *OBSERVING
Log configuration changes (LOGCFGCHG) -- *LOG
Token-ring inform of beacon (TRNINFBCN) -- *YES
Early token release (ELYTKNRLS) -- *LINESPEED
Error threshold level (THRESHOLD) -- *OFF
Recovery . . . : Change any incorrect value to the value shown. Then try the request again.
Message File : QCPFMSG
Library Message File : QSYS2924
CL_GUI_FRONTEND_SERVICES - Frontend Services CL_GUI_FRONTEND_SERVICES - Frontend Services
This documentation is copyright by IBM.
Length: 3247 Date: 20240329 Time: 101811 sap01-206 ( 3 ms )