Ansicht
Dokumentation
CPD8F55 - Automatic device creation not allowed. ( OS/400 )
rdisp/max_wprun_time - Maximum work process run time CPI1466 during BackupThis documentation is copyright by IBM.
Message : CPD8F55
Automatic device creation not allowed.
Message Long Text :
Cause . . . . . : Automatic device creation (AUTOCRTDEV parameter) can be specified only if the controller type (TYPE parameter) is 3174, 3274, 5494, or if the controller type is 5394 and the link type (LINKTYPE parameter) is *NONE.
Recovery . . . : Remove the value specified for automatic device creation (AUTOCRTDEV parameter), then try the request again.
Message File : QCPFMSG
Library Message File : QSYS2924
BAL Application Log Documentation rdisp/max_wprun_time - Maximum work process run time
This documentation is copyright by IBM.
Length: 3220 Date: 20240328 Time: 103049 sap01-206 ( 3 ms )