Ansicht
Dokumentation
CPD9071 - Designed method of sending type 2 suffix not followed. ( OS/400 )
Fill RESBD Structure from EBP Component Structure General Material DataThis documentation is copyright by IBM.
Message : CPD9071
Designed method of sending type 2 suffix not followed.
Message Long Text :
Cause . . . . . : A document interchange unit that was ended with a type 2 suffix was received from the session requester without the TRNRND response (LU6.2 change direction) indicator set on.
Recovery . . . : See the Document Interchange Architecture: Transaction Programmer's Guide, SC23-0763, for help. If the problem occurs again, use the ANZPRB command to analyze the problem.
Technical description . . . . . . . . : A document interchange unit was received from the session requester that was ended with a type 2 suffix but was not followed by the LU6.2 change direction indicator.
Message File : QCPFMSG
Library Message File : QSYS2924
PERFORM Short Reference ABAP Short Reference
This documentation is copyright by IBM.