Ansicht
Dokumentation
CPD9210 - Specified member cannot be used with member in RMTFILE. ( OS/400 )
General Material Data General Data in Customer MasterThis documentation is copyright by IBM.
Message : CPD9210
Specified member cannot be used with member in RMTFILE.
Message Long Text :
Cause . . . . . : Member name &12 has been specified for Distributed Data Management (DDM) file &2 in &3, but the RMTFILE value for the DDM file includes member name &13. The names are different.
Recovery . . . : Change the member specification, use the CHGDDMF command to remove the member name from the RMTFILE value, or change the member in the RMTFILE value to the specified member name.
Message File : QCPFMSG
Library Message File : QSYS2924
General Material Data CPI1466 during Backup
This documentation is copyright by IBM.
Length: 3237 Date: 20240423 Time: 095742 sap01-206 ( 3 ms )