Ansicht
Dokumentation

CPDA415 - Error communicating with server &1. ( OS/400 )

CPDA415 - Error communicating with server &1. ( OS/400 )

rdisp/max_wprun_time - Maximum work process run time   General Material Data  
This documentation is copyright by IBM.
SAP E-Book


Message : CPDA415
Error communicating with server &1.

Message Long Text :

Cause . . . . . : The monitor job for server &1 received an error from the server from which it cannot recover and communications has ended.
Major operation code was &2. The following lists the meaning of the code.
1= Open connection to server
2= Call NetBIOS to perform a function
3= Poll for activity on a session
4= Close connection to server

Major return code was &3. The following lists the meaning of the code.
0 = Successful operation
10= Memory not sufficient to perform function
11= Could not find server &1
12= Unable to open connection
20= Failing return code from NetBIOS
21= Lost connection to server

NetBIOS operation code was &4

NetBIOS return code was &5
Recovery . . . : No action is needed to respond to this error. The monitor job for server &1 will try to reestablish communications without operator intervention.

Message File : QCPFMSG
Library Message File : QSYS2924


CL_GUI_FRONTEND_SERVICES - Frontend Services   CL_GUI_FRONTEND_SERVICES - Frontend Services  
This documentation is copyright by IBM.

Length: 3251 Date: 20240425 Time: 040425     sap01-206 ( 5 ms )