Ansicht
Dokumentation

CPDA459 - IPX circuits conflict with line description &1. ( OS/400 )

CPDA459 - IPX circuits conflict with line description &1. ( OS/400 )

General Data in Customer Master   ABAP Short Reference  
This documentation is copyright by IBM.
SAP E-Book


Message : CPDA459
IPX circuits conflict with line description &1.

Message Long Text :

Cause . . . . . : Before running the Install NetWare Server (INSNTWSVR) command, IPX circuits already existed for line description &1. Even though the INSNTWSVR command created line description &1, IPX circuits existed with that line description value. This can occur when a line description exists with IPX circuits and when a line description is deleted, the IPX circuits are not deleted.
IPX circuits cannot have duplicate network numbers or duplicate frametypes for the same line description. Either the network number or the frametype specified on the port parameter conflicts with an existing circuit for line description &1.
Recovery . . . : Do one of the following:
-- Specify a different name in the NWSD parameter of the INSNTWSVR command.
-- Remove the IPX circuits for line description &1. To remove IPX circuits for line description &1, use the Work with IPX Circuits (WRKIPXCCT) command. The line description is displayed on the display. Remove the circuits that are associated with line description &1.

Message File : QCPFMSG
Library Message File : QSYS2924


CPI1466 during Backup   rdisp/max_wprun_time - Maximum work process run time  
This documentation is copyright by IBM.

Length: 3235 Date: 20240420 Time: 153311     sap01-206 ( 2 ms )