Ansicht
Dokumentation

CPDB145 - Line speed value not valid. ( OS/400 )

CPDB145 - Line speed value not valid. ( OS/400 )

CPI1466 during Backup   Addresses (Business Address Services)  
This documentation is copyright by IBM.
SAP E-Book


Message : CPDB145
Line speed value not valid.

Message Long Text :

Cause . . . . . : An invalid line speed (LINESPEED parameter) was entered.
Recovery . . . :
If framing type (FRAMING parameter) is *ASYNC and interface (INTERFACE parameter) is *RS232V24 then line speed must be one of the following: 9600, 19200, 38400, 57600, or 115200.
If framing type (FRAMING parameter) is *ASYNC and interface (INTERFACE parameter) is *RS449V36 or *V35 then line speed must be one of the following: 9600, 19200, 38400, 57600, 115200, 157600, or 230400.
Change the line speed to a valid value and try the command again.

Message File : QCPFMSG
Library Message File : QSYS2924


BAL_S_LOG - Application Log: Log header data   General Data in Customer Master  
This documentation is copyright by IBM.

Length: 3215 Date: 20240425 Time: 174151     sap01-206 ( 2 ms )